93 research outputs found

    Optimizations of Pt/SiC and W/Si multilayers for the Nuclear Spectroscopic Telescope Array

    Get PDF
    The Nuclear Spectroscopic Telescope Array, NuSTAR, is a NASA funded Small Explorer Mission, SMEX, scheduled for launch in mid 2011. The spacecraft will fly two co-aligned conical approximation Wolter-I optics with a focal length of 10 meters. The mirrors will be deposited with Pt/SiC and W/Si multilayers to provide a broad band reflectivity from 6 keV up to 78.4 keV. To optimize the mirror coating we use a Figure of Merit procedure developed for gazing incidence optics, which averages the effective area over the energy range, and combines an energy weighting function with an angular weighting function to control the shape of the desired effective area. The NuSTAR multilayers are depth graded with a power-law, d_i = a/(b + i)^c, and we optimize over the total number of bi-layers, N, c, and the maximum bi-layer thickness, d_(max). The result is a 10 mirror group design optimized for a flat even energy response both on and off-axis

    W/SiC x-ray multilayers optimized for use above 100 keV

    Get PDF
    We have developed a new depth-graded multilayer system comprising W and SiC layers, suitable for use as hard x-ray reflective coatings operating in the energy range 100-200 keV. Grazing-incidence x-ray reflectance at E = 8 keV was used to characterize the interface widths, as well as the temporal and thermal stability in both periodic and depth-graded W/SiC structures, whereas synchrotron radiation was used to measure the hard x-ray reflectance of a depth-graded multilayer designed specifically for use in the range E ~150-170 keV. We have modeled the hard x-ray reflectance using newly derived optical constants, which we determined from reflectance versus incidence angle measurements also made using synchrotron radiation, in the range E = 120-180 keV. We describe our experimental investigation in detail, compare the new W/SiC multilayers with both W/Si and W/B4C films that have been studied previously, and discuss the significance of these results with regard to the eventual development of a hard x-ray nuclear line telescope

    NuSTAR on-ground calibration: I. Imaging quality

    Get PDF
    The Nuclear Spectroscopic Telescope Array (NuSTAR) launched in June 2012 carries the first focusing hard Xray (5 - 80 keV) telescope to orbit. The on-ground calibration was performed at the RaMCaF facility at Nevis, Columbia University. During the assembly of the telescopes, mechanical surface metrology provided surface maps of the reflecting surfaces. Several flight coated mirrors were brought to BNL for scattering measurements. The information from both sources is fed to a raytracing code that is tested against the on-ground calibration data. The code is subsequently used for predicting the imaging properties for X-ray sources at infinite distance

    Fabrication and performance of Constellation-X hard x-ray telescope prototype optics using segmented glass

    Get PDF
    We report on the fabrication and performance of prototype optics for the Constellation-X hard X-ray telescope (HXT). The prototypes utilize segmented-glass optics. Multiple glass segments are combined to produce telescope shells. The shells are separated by and epoxied to graphite rods, and each layer of rods is precisely machined to match the required optical geometry of the corresponding glass shell. This error-compensating, monolithic assembly and alignment (EMAAL) procedure is novel. Two prototypes are described. The first used 10cm long thermally-slumped glass pieces produced by slumping into a concave mandrel with no subsequent replication. This prototype obtained 45" (2-bounce HPD). The second prototype was the first attempt to mount epoxy-replicated, thermally-slumped glass optics using EMAAL. The latter prototype demonstrated our ability to produce and mount glass shells whose figure and performance are faithful representations of the original replication mandrel. The average performance was 45", with the best replicated segment providing 33" (2-bounce HPD) performance, consistent with the ~30" measured with laser reflectometry and interferometry prior to mounting. Both these prototypes substantially exceeded the HXT requirement of 60"

    Strongly aligned gas-phase molecules at Free-Electron Lasers

    Full text link
    We demonstrate a novel experimental implementation to strongly align molecules at full repetition rates of free-electron lasers. We utilized the available in-house laser system at the coherent x-ray imaging beamline at the Linac Coherent Light Source. Chirped laser pulses, i. e., the direct output from the regenerative amplifier of the Ti:Sa chirped pulse amplification laser system, were used to strongly align 2,5-diiodothiophene molecules in a molecular beam. The alignment laser pulses had pulse energies of a few mJ and a pulse duration of 94 ps. A degree of alignment of \left = 0.85 was measured, limited by the intrinsic temperature of the molecular beam rather than by the available laser system. With the general availability of synchronized chirped-pulse-amplified near-infrared laser systems at short-wavelength laser facilities, our approach allows for the universal preparation of molecules tightly fixed in space for experiments with x-ray pulses.Comment: 10 pages, 5 figure

    Production and calibration of the first HEFT hard x-ray optics module

    Get PDF
    Complete hard X-ray optics modules are currently being produced for the High Energy Focusing Telescope (HEFT), a balloon born mission that will observe a wide range of objects including young supernova remnants, active galactic nuclei, and galaxy clusters at energies between 20 and 70 keV. Large collecting areas are achieved by tightly nesting layers of grazing incidence mirrors in a conic approximation Wolter-I design. The segmented layers are made of thermally-formed glass substrates coated with depth-graded multilayer films for enhanced reflectivity. Our novel mounting technique involves constraining these mirror segments to successive layers of precisely machined graphite spacers. We report the production and calibration of the first HEFT optics module

    NuSTAR Hard X-ray Survey of the Galactic Center Region I: Hard X-ray Morphology and Spectroscopy of the Diffuse Emission

    Get PDF
    We present the first sub-arcminute images of the Galactic Center above 10 keV, obtained with NuSTAR. NuSTAR resolves the hard X-ray source IGR J17456-2901 into non-thermal X-ray filaments, molecular clouds, point sources and a previously unknown central component of hard X-ray emission (CHXE). NuSTAR detects four non-thermal X-ray filaments, extending the detection of their power-law spectra with Γ∼1.3\Gamma\sim1.3-2.32.3 up to ~50 keV. A morphological and spectral study of the filaments suggests that their origin may be heterogeneous, where previous studies suggested a common origin in young pulsar wind nebulae (PWNe). NuSTAR detects non-thermal X-ray continuum emission spatially correlated with the 6.4 keV Fe Kα\alpha fluorescence line emission associated with two Sgr A molecular clouds: MC1 and the Bridge. Broad-band X-ray spectral analysis with a Monte-Carlo based X-ray reflection model self-consistently determined their intrinsic column density (∼1023\sim10^{23} cm−2^{-2}), primary X-ray spectra (power-laws with Γ∼2\Gamma\sim2) and set a lower limit of the X-ray luminosity of Sgr A* flare illuminating the Sgr A clouds to LX∼>1038L_X \stackrel{>}{\sim} 10^{38} erg s−1^{-1}. Above ~20 keV, hard X-ray emission in the central 10 pc region around Sgr A* consists of the candidate PWN G359.95-0.04 and the CHXE, possibly resulting from an unresolved population of massive CVs with white dwarf masses MWD∼0.9M⊙M_{\rm WD} \sim 0.9 M_{\odot}. Spectral energy distribution analysis suggests that G359.95-0.04 is likely the hard X-ray counterpart of the ultra-high gamma-ray source HESS J1745-290, strongly favoring a leptonic origin of the GC TeV emission.Comment: 27 pages. Accepted for publication in the Astrophysical Journa
    • …
    corecore